What Is 21 CFR Part 11? Electronic Record and Signature Requirements in EBR Systems

What Is 21 CFR Part 11? Electronic Record and Signature Requirements in EBR Systems

21 CFR Part 11 is a regulation put into effect by the US Food and Drug Administration (FDA) in 1997. It defines the conditions under which electronic records and electronic signatures are considered as trustworthy as paper records and handwritten signatures. If a record within the scope of GMP is created, modified, stored, or signed electronically, Part 11 requirements apply. EBR (Electronic Batch Record) systems are among the areas where this regulation applies most directly.

For a manufacturer moving from paper batch records to EBR, the most critical question is this: Will the auditor trust the electronic record as much as the paper record? In this article, we explain the scope of Part 11, the controls it introduces for electronic records and signatures, and how an EBR system meets these controls.

What Does 21 CFR Part 11 Cover?

1. Scope and Key Concepts

Part 11 does not by itself state which records must be kept; that is determined by underlying rules such as GMP (predicate rules). Part 11 defines how the records kept under those rules must be safeguarded when they are moved to an electronic environment. The scope and application guidance published by the FDA in 2003 calls for a risk-based approach to implementation. The regulation also distinguishes between closed systems, where access is controlled by the organization, and open systems, where access is not controlled; additional measures such as encryption are expected in open systems. Its European counterpart is EU GMP Annex 11.

2. Controls for Electronic Records (Subpart B)

Section 11.10 lists the basic controls for closed systems:

  • Validation: Documenting that the system operates accurately, reliably, and consistently.
  • Readable copies: Being able to generate complete and readable copies of records for inspection.
  • Record protection: Keeping records accurate and accessible throughout the retention period.
  • Access control: Allowing only authorized individuals to access the system.
  • Audit trail: Recording the creation of records and changes to them by the computer, with a time stamp and without obscuring previous values.
  • Operational and authority checks: Ensuring that steps are performed in the correct sequence and only by authorized individuals.
  • Training and accountability: Training users and holding them accountable for their signatures.

For the validation approach, you can see our article on GAMP 5 and EBR validation.

3. Electronic Signature Requirements (Subpart C)

Section Requirement

11.50 The signature must show the signer's name, the date and time, and the meaning of the signature (approval, review, responsibility).

11.70 The signature must be linked to its record and must not be copyable or transferable to another record.

11.100 Each electronic signature must belong to one individual and must not be reassigned to anyone else.

11.200 Non-biometric signatures must consist of at least two components, for example a user ID and a password.

11.300 The uniqueness of IDs and passwords, their periodic review, and the reporting of unauthorized use attempts must be ensured.

Part 11 is not a software feature but a contract of trust: the system protects the record, and the organization proves that the system actually does so.

How Is Part 11 Compliance Achieved in EBR Systems?

4. Electronic Signatures at Critical Steps

In an EBR, critical steps such as weighing, material verification, process control, and batch approval require an electronic signature. When necessary, second-person verification is also enforced through a signature. The electronic signature, authorization, and audit trails module manages the meaning of the signature, role-based authority, and the link to the record in one place; details are provided in the related article.

5. Tamper-Proof Audit Trail

Every change in an EBR must be stored with information on who changed which value to which value, when, and for what reason. Users must not be able to turn the audit trail off or edit it. Reviewing the audit trail together with exceptions during batch review is the strongest evidence of data integrity. Transferring values from devices such as scales, pH meters, or control systems directly into the system, without manual entry, also increases the reliability of the audit trail, because no human intervention remains between the source data and the record. Synchronizing the system clock with a central time server and preventing users from changing the time are also essential for the reliability of the time stamp. For the relationship of these principles with ALCOA+, you can read our article on ALCOA and EBR.

6. Validation, Procedures, and Training

Technical controls alone are not sufficient. The user company must validate the system for its own intended use, write procedures for user and password management, backup, and periodic audit trail review, and train its users. For managing these procedures, you can look at our article on eQMS, and for the regulatory framework, our article on what GxP is.

Does 21 CFR Part 11 apply to manufacturers in Türkiye?

It applies to manufacturers that export products to the US market or are subject to FDA inspection. Because the GMP guide applied in Türkiye is aligned with EU GMP, similar requirements appear through Annex 11; the two regulations largely overlap.

Can software be Part 11 certified?

No. The FDA does not certify software. Software provides technical controls that support Part 11 compliance; compliance itself is achieved and documented by the user company through validation, procedures, and training.

Are a user name and password enough for an electronic signature?

Yes. Non-biometric signatures require at least two distinct components, and a user ID and password are generally used. In a single continuous session, the first signature is executed with two components, and subsequent signatures can be executed with at least one component.

Conclusion: 21 CFR Part 11 defines the reliability of electronic records and signatures through the principles of validation, access control, audit trails, and signatures unique to each individual. By building these principles into every production step, EBR systems eliminate the risks carried by the paper batch record. Centra EBR offers controls that support Part 11 and Annex 11 requirements on the Konektom platform, together with QMS and MES. To evaluate the electronic record infrastructure of your pharmaceutical manufacturing facility, request information.